CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System

Dettagli del prodotto

Luogo di origine: Pechino

Marca: GOMECY

Certificazione: CE CCC

Numero di modello: GMS C3 Verticale

Termini di trasporto & di pagamento

Quantità di ordine minimo: 1

Prezzo: USD 2899-3499

Imballaggi particolari: Imballaggio standard

Tempi di consegna: 5-8 giorni

Termini di pagamento: T/T, Western Union, L/C

Capacità di alimentazione: 50 +UNIT+a settimana

Ottenga il migliore prezzo
Evidenziare:

High Power CO2 Fractional Laser Machine

,

Skin Repair CO2 Fractional Laser Machine

,

Scar Removal CO2 Fractional Laser Machine

Trasmettitore principale:
40 W
Tecnologia:
CO2+RF
Dimensione del punto:
0.02~0.05mm2
Grafici di ricerca:
Cerchio, triangolo, quadrato, rettangolo, esagono, ellisse, linea
Trasmettitore principale:
40 W
Tecnologia:
CO2+RF
Dimensione del punto:
0.02~0.05mm2
Grafici di ricerca:
Cerchio, triangolo, quadrato, rettangolo, esagono, ellisse, linea
CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System

GOMECY Fractional RF CO2 Laser – Clinically Proven Technology for Dermatological and Gynecological Rejuvenation

 

The GOMECY Fractional RF CO2 Laser System is a powerful, multifunctional platform designed for professional use in dermatology, aesthetic medicine, and gynecology. Utilizing a 10600nm wavelength with RF-enhanced fractional CO2 technology, the system offers highly controlled ablative resurfacing and thermal stimulation for collagen regeneration with minimal risk and downtime.

This platform is clinically engineered to treat a wide spectrum of conditions, including scars, wrinkles, pigmentation disorders, skin lesions, and vaginal laxity, with high precision and safety.

 

 

CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 0


 

Scientific Working Mechanism – Fractional CO2 + RF

The system employs a fractional photothermolysis technique, where laser energy is delivered in a pixelated pattern, creating microthermal zones (MTZs) that penetrate into the dermal layer. These controlled injuries stimulate fibroblast activity, triggering a cascade of collagen remodeling and neocollagenesis.

The addition of radiofrequency (RF) energy enhances thermal depth, improving tissue contraction and wound healing response, without increasing ablative trauma to the epidermis. This synergistic effect allows for faster recovery, less erythema, and lower complication rates.

 

CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 1CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 2CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 3

 

Advanced Vaginal Tightening Capsule – Functional & Aesthetic Restoration

The GOMECY system includes a specialized vaginal tightening applicator, designed for non-invasive gynecological applications such as vaginal atrophy, mucosal laxity, and stress urinary incontinence.

 

The fractional laser energy penetrates the vaginal mucosa, inducing collagen contraction in the short term and promoting elastin and collagen regeneration over time. This leads to the thickening of epithelial tissue, enhanced vaginal wall strength, and improved moisture retention.

 

Additionally, the treatment improves local circulation and activates fibroblast and macrophage activity, contributing to complete mucosal remodeling. Multiple studies confirm improved tissue elasticity, tightness, patient satisfaction, and love function scores after 2-4 sessions.

 

CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 4

 

Clinical Indications

Dermatology Applications

 

  1. Acne scars and post-surgical scars

  2. Deep and superficial wrinkles

  3. Photoaging and UV-damaged skin

  4. Epidermal lesions: actinic keratoses, benign tumors

  5. Hyperpigmentation: chloasma, age spots, melasma

  6. Skin resurfacing and rejuvenation

 

Gynecological Applications

 

  1. Vaginal tightening and rejuvenation

  2. Vaginal whitening and tone enhancement

  3. Urinary stress incontinence

  4. Postpartum tissue repair

  5. Vaginal dryness and atrophy

 

CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 5CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 6

 

CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 7

 

 

Product Parameters

 

CO2 Fractional Laser Scar Removal Machine For Skin Repair Clinics With High Power Energy Output And Cooling System 8

 

 

Post-Treatment Care and Safety Reminders

After treatment, patients may experience temporary redness, swelling, or mild discomfort—this is normal and typically subsides within a few hours to days. Instruct the patient to avoid sun exposure, hot showers, and harsh skincare products for at least 7 days. Use a high-SPF sunscreen and moisturizer to protect and hydrate the skin. For vaginal treatments, advise patients to abstain from activity for 5–7 days and maintain proper hygiene to prevent infection. Monitor the skin healing progress, and do not repeat treatment on the same area until the skin is fully recovered.